REMCO's 3300 series 2.2 GPM Sprayer pump is the Professional Grade performance leader. This sprayer pump utilizes a 60 PSI pressure setting and REMCO's signature sealed 12 volt electric motor allowing the pump to operate in the harshest environments. The 3300 Series is Made in the U.S.A and engineered with Professional Grade components able to withstand long and continuous duty cycles of Agricultural spray applications. Utilizing heavy 14 AWG wire leads the REMCO 3300 Series has low operating temperatures is extremely efficient. This 2.2 GPM pump's materials of construction are compatible with most common agricultural spray chemical including herbicides, fertilizers, and insecticides. The Professional Grade 3300 Series Spray pump is perfect for any demanding spraying application.Package Contents: 1 - Professional Grad 3300 Series, 2.2 GPM, 60 PSI on Demand, 12 Volt Sprayer pump with 3/4 in. QA ports, 1 - 3/
For additional information on this product, please see the Product Documents section for all downloadable user manuals, installation guides, brochures and warranty statements.
Looking for more information on sprayers? Check out our guide on agricultural and lawn sprayers in the product documents section.
- 2.2 GPM, 60 PSI on Demand, 12 VDC, 3/4" QA ports
- 3/8 in. Hose Barb fittings included (one elbow and one straight)
- Capable of being run dry
- Self priming up to 8 ft. vertically
- 6 in. length 14 AWG wire leads wit SAE 2 pin connector
- Highest flow rate and lowest operating temperature at spray pressures when compared to other pumps
- Chemically compatible with common Agricultural chemicals like herbicides, fertilizers, and insecticides
- Maximum Shell Temperature of 180 F
- Maximum Liquid Temperature of 140 F
- 100% Factory Tested
- Made in the U.S.A
| Brand | REMCO |
|---|---|
| Country of Origin | Made in USA |
| Compatibility | Chemically compatible with common Agricultural chemicals like herbicides, fertilizers, and insecticides |
| Discharge Port Diameter | 0.75 in. Quick Attach |
| Inlet Diameter | 0.75 in. Quick Attach |
| Maximum Flow Rate | 2.2 GPM |
| Maximum Head Lift | 8 ft. Vertically |
| Maximum Operating Pressure | 60 PSI |
| Maximum Operating Temperature | 180 deg. F |
| Maximum Suction Lift | 8 ft. Vertically |
| Minimum Operating Pressure | 0 PSI |
| Package Quantity | 1 |
| Power Cord Length | 6 in. |
| Primary Color | Black |
| Primary Material | Polypropylene |
| Product Height | 3.8 in. |
| Product Length | 9.3 in. |
| Product Weight | 6 lb. |
| Product Width | 4.1 in. |
| Pump/Repair Product Type | Pumps |
| Warranty | 1 Year |
| Manufacturer Part Number | 90-3313-1E1-82B-SB |
Q: What amp is it
20 days ago- A: Thanks for the question, this pump has a maximum amp draw of 8 amps, so we would recommend installing with a 10amp fuse. If you have further questions please contact us directly 763-253-4740 or sales@remcoindustries.com20 days agoHelpful?
Q: Does the pump come with wiring?
a month ago- A: This pump does have wire leads but they are only 6" long, you will need a wire harness kit to connector the pump to a battery. Please reach out to us directly with further questions 763-253-4740 or sales@remcoindustries.com30 days agoHelpful?
Q: Will this replace dela/and model grn-7802-201
2 months ago- A: Great question and yes this will directly replace that model. Please reach out to us if you have question about fit or plumbing 763-253-4740 or sales@remcoindustries.com2 months agoHelpful?
Q: Is the pressure switch on this adjustable?
9 months ago- A: Thanks for the question, Yes the pressure switch can be adjusted. There is a set screw on the face of the pressure switch that is 1/16th hex key (allen wrench), turning it clock-wise will increase the shut off pressure, counter-clockwise will decrease the shut off pressure. This should not be adjusted more than 3 full turns in any direction. Please contact us directly an we can help make sure your pressure switch is set properly 763-253-4740 or sales@remcoindustries.com9 months agoHelpful?
Q: Will this pump work in an rv?
a year ago- A: Thanks for your question, this pump is not meant for RV applications. I would recommend our Power RV series which can be found on www.tractorsupply.com just search for Remco and look for the Power RV series (3200, Rebel, or Aquajet) reach out with any questions, sales@remcoindustries.com or 763-253-4740a year agoHelpful?
Q: What are the effects of rapid on/off cycling of the oressure switch? My pump was doing that, then quit running. Can it be repaired?
a year ago- A: Thanks for your question, rapid cycling is the pump trying to run at or above the shut off pressure causing the pressure switch to cycle and off rapidly. Here is a link to a video showing what cycling is and how to solve it. https://www.youtube.com/watch?v=jWfCNS2HkhU If you pump quit running you can replace the pressure switch, which van be purchased on tractorsupply.coma year agoHelpful?
Q: I can't get the pump to turn on. I have replaced the fuse, but nothing happens.
a year ago- A: Thanks for your question, typically this issues comes down to the wiring or power source. Please verify that all electrical connections are clean and free of corrosion. Also verify that you have a minimum of 12 Volts at the pump connection, if you don't then there is a problem between battery and the pump connection. Please reach out to us for further technical support sales@remcoindustries.com with photos of you system or 763-253-4740a year agoHelpful?
Q: I have a 3313-1B1-82B pump on my sprayer. was using my sprayer to water my flowers with miracle grow. it was working fine, then stopped. Motor runs but no pressure. HELP! Do I need a new unit or can it be rebuilt?
a year ago- A: Yes this can be rebuilt, with a VHA7863-7F77 valve housing. This can be purchased on the Tractor Supply website. Please reach out to us with any further questions sales@remcoindustries.com or 763-253-4740a year agoHelpful?
Q: I have a Northstar 16 gallon sprayer. The pump on it is a 2.2 GPM, 70 PSI Max Pressure. Will this pump replace the current pump. It has the quick disconnect fitting and I believe is is a 3/4
a year ago- A: Yes this pump will plug and play with the NorthStar unit. Please reach out to us directly if you have further questions sales@remcoindustries.com or 763-253-4740a year agoHelpful?
Q: What thread size are the mounting bolts?
2 years ago- A: Thanks for your question, most common thread size is 10-24. This would adapt to the majority of spray tanks on the market.2 years agoHelpful?
Q&As
Q: What amp is it
20 days ago- A: Thanks for the question, this pump has a maximum amp draw of 8 amps, so we would recommend installing with a 10amp fuse. If you have further questions please contact us directly 763-253-4740 or sales@remcoindustries.com20 days agoHelpful?
Q: Does the pump come with wiring?
a month ago- A: This pump does have wire leads but they are only 6" long, you will need a wire harness kit to connector the pump to a battery. Please reach out to us directly with further questions 763-253-4740 or sales@remcoindustries.com30 days agoHelpful?
Q: Will this replace dela/and model grn-7802-201
2 months ago- A: Great question and yes this will directly replace that model. Please reach out to us if you have question about fit or plumbing 763-253-4740 or sales@remcoindustries.com2 months agoHelpful?
Q: Is the pressure switch on this adjustable?
9 months ago- A: Thanks for the question, Yes the pressure switch can be adjusted. There is a set screw on the face of the pressure switch that is 1/16th hex key (allen wrench), turning it clock-wise will increase the shut off pressure, counter-clockwise will decrease the shut off pressure. This should not be adjusted more than 3 full turns in any direction. Please contact us directly an we can help make sure your pressure switch is set properly 763-253-4740 or sales@remcoindustries.com9 months agoHelpful?
Q: Will this pump work in an rv?
a year ago- A: Thanks for your question, this pump is not meant for RV applications. I would recommend our Power RV series which can be found on www.tractorsupply.com just search for Remco and look for the Power RV series (3200, Rebel, or Aquajet) reach out with any questions, sales@remcoindustries.com or 763-253-4740a year agoHelpful?
Q: What are the effects of rapid on/off cycling of the oressure switch? My pump was doing that, then quit running. Can it be repaired?
a year ago- A: Thanks for your question, rapid cycling is the pump trying to run at or above the shut off pressure causing the pressure switch to cycle and off rapidly. Here is a link to a video showing what cycling is and how to solve it. https://www.youtube.com/watch?v=jWfCNS2HkhU If you pump quit running you can replace the pressure switch, which van be purchased on tractorsupply.coma year agoHelpful?
Q: I can't get the pump to turn on. I have replaced the fuse, but nothing happens.
a year ago- A: Thanks for your question, typically this issues comes down to the wiring or power source. Please verify that all electrical connections are clean and free of corrosion. Also verify that you have a minimum of 12 Volts at the pump connection, if you don't then there is a problem between battery and the pump connection. Please reach out to us for further technical support sales@remcoindustries.com with photos of you system or 763-253-4740a year agoHelpful?
Q: I have a 3313-1B1-82B pump on my sprayer. was using my sprayer to water my flowers with miracle grow. it was working fine, then stopped. Motor runs but no pressure. HELP! Do I need a new unit or can it be rebuilt?
a year ago- A: Yes this can be rebuilt, with a VHA7863-7F77 valve housing. This can be purchased on the Tractor Supply website. Please reach out to us with any further questions sales@remcoindustries.com or 763-253-4740a year agoHelpful?
Q: I have a Northstar 16 gallon sprayer. The pump on it is a 2.2 GPM, 70 PSI Max Pressure. Will this pump replace the current pump. It has the quick disconnect fitting and I believe is is a 3/4
a year ago- A: Yes this pump will plug and play with the NorthStar unit. Please reach out to us directly if you have further questions sales@remcoindustries.com or 763-253-4740a year agoHelpful?
Q: What thread size are the mounting bolts?
2 years ago- A: Thanks for your question, most common thread size is 10-24. This would adapt to the majority of spray tanks on the market.2 years agoHelpful?
Similar Items
Items You May Like
Customers Also Bought
Reviews
Summary of Reviews
- English
- German
- French
- Spanish
- Portuguese
- Italian
- Korean
- Chinese
- Japanese
- Arabic
Customer Images and Videos
- purchase
- spraying
- returns
- installation
- warranty
- staff
- in-store
- price
Sprayer pump
Yes, I recommend this product.
Each one lasted about 3 times
Tough Pump
Yes, I recommend this product.
Great Product
Yes, I recommend this product.